Innovative solutions
    for more effective diagnostics

Presentation

Products

Pathogens

Client Care

Science

IFU

Contact

Blog

NEWS

AACC 2017 - Meet us in San Diego

July 30 to August 3, 2017

 

Products Range

NEW-Resist Range

Oxa-48

KPC

RESIST-3 O.O.K.

RESIST-3 O.K.N.

Immunochromatographic Range

Pathogens detection

40/41 Adenovirus

Adenovirus

Clostridium difficile

Cryptosporidium & Giardia

Cryptosporidium

Escherichia coli O157

Rotavirus & 40/41 Adenovirus

Giardia

Helicobacter pylori

Influenza A & B viruses

Legionella

Respiratory Adenovirus

Rotavirus & Adenovirus

Rotavirus

Respiratory Syncytial Virus (RSV)

Streptococcus (group A)

Trypanosoma brucei gambiense (HAT)

Quatro-VeT (Veterinary)

Molecular Range

Leishmania

Pseudomonas aeruginosa

Scientific partners

PARADIS (Biowin)

CCH Fever (EC-FP7)

Chips 4 life (EC-FP7)

Nidiag (EC-FP7)

AquaVir (FP7)

Nareb (FP7)

Euroleish (H2020-MSCA-ITN)

ebolaMoDRAD (IMI-2)

 

Products  >  Veterinary-Field  >  Quatro VeT

Vete test kitRotavirus, Cryptosporidium, Coronavirus
and Escherichia coli K99

«Ready to use» immunochromatographic kit
for detection of Rotavirus, Cryptosporidium,
Coronavirus and Escherichia coli K99 (F5) in bovine
stool specimens.

Ordering information     Contact us !

Pathogen

Product Name

Technology

Description

Code

Rotavirus
Cryptosporidium
Escherchia coli K99
Coronavirus

Quatro Vet Uni-Strip

Dipstick

10 individual strips with 4 tests, buffers, sample taking material (test tubes, loops, tube holder)

C-1540

Advantages of the kits

Sensitive and specific
Easy to perform
Convenient
Simple, accurate and economical
No special skill for interpretation
Minimal faecal manipulation
No instrumentation

Procedure

Quatro Vet Uni-Strip

Performances

Rotavirus test:
Results on 67 faecal samples.
Sensitivity: 92.85% - Specificity: 100%
Reliability: 98.5%

ELISA /
Rota

Positive

Negative

Total

Positive

13

0

13

Negative

1

53

54

Total

14

53

67

Cryptosporidium test:
Results on 113 fecal samples.
Sensitivity: 94.74% - Specificity: 92%
Reliability: 92.9%

ELISA /
Crypto

Positive

Negative

Total

Positive

36

6

42

Negative

2

69

71

Total

38

75

113

 

Escherichia coli F5 test:
Results on 42 faecal samples.
Sensitivity: 100% - Specificity: 94.11%
Reliability: 95.23%

ELISA /
E. coli F5

Positive

Negative

Total

Positive

8

2

10

Negative

0

32

32

Total

8

34

42

Coronavirus test:
Results on 69 faecal samples.
Sensitivity: 92.59% - Specificity: 100%
Reliability: 97.10%

ELISA /
Corona

Positive

Negative

Total

Positive

25

0

25

Negative

2

42

44

Total

27

42

69

Product file

Quatro Vet Uni-Strip - Veterinary range diagnostic - Product file (PDF file)

Product catalogue

icone-pdf Product catalogue (PDF file)

FAQ

Quatro Vet - FAQ page

Science

Quatro Vet - Science page

Home   -   Site Map   -   Privacy Policy   -   Contact   -   FAQ                   All rights reserved CorisBioconcept SPRL 1996-2012©                           www.corisbio.com

Web traffic Optimisation
Universem

Design, Programming & hosting
Impact communication